1
|
- ARCHITECTURAL ASSESSMENT
- “Why Grow Out , Grow Up”
- Mike Jackson, FAIA
- Illinois Historic Preservation Agency
|
|
2
|
- The architectural target of this program is the vacant upper story space
that exists in tens of thousands of small floor plate buildings in
America’s older downtowns.
|
|
3
|
- The goal of this session is to make you aware of the architectural,
regulatory and fiscal variables that affect feasibility.
|
|
4
|
- Real Estate (land & improvements)
- A part of the community wealth (tax base)
- A piece of architecture
- A part of history (many former owners/uses)
- A ecological asset: embodied energy
- Host of environmental hazards
|
|
5
|
- Land value
- Building value (current market)
- Depreciated value (adjusted basis)*
- Increases with improvements
- Decreases with depreciation
- Trigger value for tax credit eligibility
- Insured value (replacement?)
- Assessed value (property tax basis)
|
|
6
|
- Embodied Energy
- A typical 2 story downtown building has the embodied energy equivalent
of:
- 24,000 gallons of gasoline or
- 230 tons of CO2
|
|
7
|
- Building Codes
- Locally adopted, national model
- Illinois Plumbing Code
- Illinois Accessibility Code
- American with Disabilities Act
- Secretary of the Interior’s Standards (Historic)
- Code triggers based upon funding source
- Ex: HUD funding and lead paint
|
|
8
|
- City, county, state, township
- Street address (Highway?)
- Lot size & setbacks (survey?)
- Zoning district
- Parking requirement
- No on-site requirement in most downtowns
- Zero lot line
- Rear yard
|
|
9
|
- Topography
- Flood plain
- Seismic
- Local designations:
- Main Street district
- Historic District
- Special districts
|
|
10
|
- Electric
- Gas
- Water (size and pressure)
- Sewer (interior and exterior adequacy)
- Telephone
- Cable
- High speed Internet
- Trash pick up
|
|
11
|
- Size
- Construction type (from building code)
- Structural system (check for adequacy)
- Architectural attributes that are code triggers
- Number of exits
- Access to light and ventilation
|
|
12
|
- CONSTRUCTION TYPE (IBC 2000)
- Type III (based upon fire resistance of building elements)
- Exterior walls are noncombustible materials and interior building
elements are of any material permitted by this code.
|
|
13
|
- STRUCTURE (IBC 2000)
- Residential 40 psf
- Stairs and exits 100 psf
- One & two family dwelling 40 psf
- Office 50 psf, Corridor above 1st fl 80 psf
- Lobbies and first floor corridor 100 psf
- Original design (archaic materials)
- Condition assessment
|
|
14
|
|
|
15
|
|
|
16
|
|
|
17
|
- Three-story buildings require two means of egress from the third
floor. Exits have to directly connect to a public right-of-way.
|
|
18
|
- Current use (zoning classifications)
- Historic use (city directory, Sanborn map)
- Vacant (last known legal use)
- Kitchen and bath indicate residential use
|
|
19
|
- Sanborn fire insurance maps are a valuable tool to evaluate a buildings
original fire safety design attributes.
|
|
20
|
- Asbestos
- Lead Paint
- Underground storage tanks
- Other
- Prior industrial use (Sanborn map, history)
- Bird droppings
- Mold
|
|
21
|
- ASBESTOS:
- Regulated by:
- US Environmental Protection Agency
- NESHAP (National Emission Standards for Hazardous Air Pollutants)
- Illinois Department of Public Health
- Contractor certification & practices
- Demolition & Renovation notification
- Special rules on floor tile
- Illinois Environmental Protection Agency
|
|
22
|
- ASBESTOS – “trigger” points
- Friable and non-friable materials
- Minimum quantities of materials
- USEPA – NESHAP does not apply to:
- Residential buildings with 4 our fewer units
- Demolition & Renovation
- Demolition is the removal of a structural member
- Notification requirement
|
|
23
|
- ASBESTOS
- Survey when demolition or renovation is planned (qualified contractor)
$
- Abatement (qualified contractor) $ - $$$
- Floor tile demolition (special qualifications) $
- Critical issue: $$$
- Asbestos in plaster
|
|
24
|
- LEAD PAINT
- REGULATORY
- Illinois Dept. of Public Health
- Illinois Environmental Protection Agency
- OSHA (worker protection) Commercial bldgs
- HUD Guidelines (most well known)
- Apply only when HUD funding is involved
|
|
25
|
- LEAD PAINT
- Definition: >0.5% lead content
- Most common in buildings before 1950
- Exterior woodwork most common source
- Friction surfaces (windows)
- Most downtown buildings will have lead paint.
- Hazard based upon condition and likelihood of becoming lead dust.
|
|
26
|
- LEAD PAINT (IDPH)
- Identification (XRF, chips, dust wipe)
- Risk assessment
- Treatment options
- No hazard from intact materials
- Interim control (special paint coatings)
- Abatement (cover, remove paint or element)
- Requires specialized contractors) $$$
- Disposal (requirements based upon quantity)
|
|
27
|
- MOLD
- This is a new relatively new topic of environmental concern, for which
rules and regulations are currently being developed.
- Controversy over the definition
- Confusing market place
- Technical note:
- Plaster has a high lime content and is not a likely host for mold.
Drywall, with its cellulose (paper) surface is a very good host for
mold.
|
|
28
|
- Historic designation status:
- Individual building
- Contributing building to a district
- National Register
- Local landmark
- Eligibility (50 years +)
- Age (pre 1936)
- Architectural style classification
|
|
29
|
- Historic status allows building code alternatives.
- Status based upon eligibility
- HAARGIS – Illinois’ on-line tool to access historic status
- http://gis.hpa.state.il.us/hargis/
|
|
30
|
- Secretary of the Interior’s Standards for Rehabilitation
- Local commission review of exterior
|
|
31
|
- Roof
- Slope
- Condition/warranty
- Gutters & downspouts
- Structural adequacy
- Foundation
- Material
- Structural adequacy
|
|
32
|
- Facades: Primary, Secondary,
Tertiary
- Condition assessment
- Special features (architectural)
- Time period of significance/alterations
|
|
33
|
- Interiors
- Primary, secondary, tertiary
- Special features
- High ceilings
- Architectural elements
- Skylights
- Fireplaces
|
|
34
|
- Balancing economic are architectural factors
- Capacity limits of the existing building
- Cost of improving the capacity
- Financial limits based upon
- Expected return on investment
- Availability of incentives
|
|
35
|
- Cost is directly related to complexity of use:
- Storage
- Residential (owner’s unit)
- Multi-family residential (unit count)
- Office
- Retail
- Assembly (restaurant)
|
|
36
|
- What does the building want to be?
- Original use
- Residential, high adequacy if two story
- Office, medium adequacy (access)
- Assembly, high inadequacy (access & fire safety)
|
|
37
|
- Site Factors:
- Parking
- Covered or open
- Proximity
- Neighborhood
- Outdoor space (residential occupancy)
- Rental or condo potential
|
|
38
|
|
|
39
|
|